Seagate ST3400071FC Betriebsanweisung Seite 94

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 718
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 93
7.10
Command Line Interface Reference InForm OS Version 2.2.4
EXAMPLES
In the following example, the loopback test is performed on port 0:0:1 a total of five times:
NOTES
When both the -time and -iter options are specified, the first limit reached terminates
the program. If neither are specified, the default is 1,000 iterations. The total run time is
always limited to 300 seconds even when not specified.
The default loopback is an ELS-ECHO sent to the HBA itself.
QLogic HBAs do not support ELS-ECHOs to themselves, so a custom external loopback
operation is used. This requires that no other devices are present on the port.
cli% checkport -iter 5 0:0:1
Starting loopback test on port 0:0:1
Port 0:0:1 completed 5 loopback frames in 0 seconds
Passed
Seitenansicht 93
1 2 ... 89 90 91 92 93 94 95 96 97 98 99 ... 717 718

Kommentare zu diesen Handbüchern

Keine Kommentare