21.12
Command Line Interface Reference InForm OS Version 2.2.4
COMMAND
setbattery
DESCRIPTION
The setbattery command sets battery information such as the battery’s expiration date, its
recharging time, and its serial number. This information gives the system administrator a
record or log of the battery age and battery charge status.
SYNTAX
setbattery [options <arg>] <node_ID> <powersupply_ID> <battery_ID>
AUTHORITY
Super, Service
OPTIONS
–s <serial_number>
Specifies the serial number of the battery using a limit of eight alphanumeric characters.
–x <exp_date>
Specifies the expiration date of the battery (mm/dd/yyyy). The expiration date cannot
extend beyond 2037.
mm
Specifies the month of expiration using a number from 1 through 12.
dd
Specifies the day of expiration using a number from 1 through 31.
yyyy
Specifies the year of expiration using a 4-digit number greater than 2000.
–l
Specifies that the battery test log is reset and all previous test log entries are cleared.
NOTE: You need access to all domains in order to run this command.