25.26
Command Line Interface Reference InForm OS Version 2.2.4
–rw
Specifies that reads and writes are displayed separately. If this option is not used, then the
total of reads plus writes is displayed.
–d <secs>
Specifies the interval, in seconds, that statistics are sampled using an integer from 1
through
2147483. If no interval is specified, the option defaults to an interval of two
seconds.
–iter <number>
Specifies that I/O statistics are displayed a specified number of times as indicated by the
number argument using an integer from 1 through 2147483647.
–begin
Specifies that I/O averages are computed from the system start time. If not specified, the
average is computed since the first iteration of the command.
–idlep
Specifies the percent of idle columns in the output.
–sortcol <col> [,<dir>][:<col>[,<dir>]...]
Sorts command output based on the column number <col>. Columns are numbered from
left to right, beginning with 0. You must specify a column number. In addition, you can
specify the direction of sorting
<dir> as follows:
inc
Sort in increasing order (default).
dec
Sort in decreasing order.
Multiple columns can be specified separated by a colon (
:), and rows that have the same
earlier columns will be sorted by the values in the later columns.
–filt <fspec>
Specifies that statistics that fall below the threshold as specified by the <fspec>
arguments where <fspec> is <type>, <op>, <meas>, <val>, are filtered out and not
displayed. The
type, operation, meas, and value arguments are separated with one
comma.