19.31
InForm OS Version 2.2.4 Command Line Interface Reference
COMMAND
removevlun
DESCRIPTION
The removevlun command removes a virtual volume’s SCSI LUN export definition from the
system.
SYNTAX
removevlun [options] <VV_name> <LUN> <node:slot:port>|<host_name>
AUTHORITY
Super, Edit
OPTIONS
–novcn
Specifies that a VLUN Change Notification (VCN) not be issued after removal of the VLUN.
For direct connect or loop configurations, a VCN consists of a Fibre Channel Loop
Inititalization Primitive (LIP).
For fabric configurations, a VCN consists of a Registered State Change Notification
(RSCN) that is sent to the fabric controller.
–pat
Specifies that the <VV_name>, <LUN>,< node:slot:port>, and <host_name> specifiers
are treated as glob-style patterns and that all VLUNs matching the specified pattern are
removed. By default, confirmation is required to proceed with the command unless the
–f
option is specified.
–dr
Specifies that the operation is a dry run and no VLUNs are removed.
–f
Specifies that the command is forced. If this option is not used, the command requires
confirmation before proceeding with its operation.
SPECIFIERS
<VV_name>
Specifies the volume name, using up to 19 characters.