19.4
Command Line Interface Reference InForm OS Version 2.2.4
EXAMPLES
The following example displays all alerts from the system with the option to remove individual
alerts:
NOTES
None.
cli% removealert –a
Id 120 – New
Occurred 4 times, last at Tue May 03 22:45:47 PDT 2005
Message code: 196609
Tue May 03 22:23:17 PDT 2005
Node: 0 Severity: Minor
Firmware coredump event
Firmware COREDUMP: recovered file /var/core/hba/fwcore.n00.s02.p01.20050503.224547
Alert 120 is marked as "New".
Are you sure you want to remove it?
select q=quit y=yes n=no: y
Id 131 – New
Message code: 1114115
Thu May 05 00:11:25 PDT 2005
Node: 0 Severity: Minor
Too many events are being logged
Too many events are being generated. 2 event files were rolled over in less
than 1800 seconds. Current event files could not be archived because too many
have been archived already.
Alert 131 is marked as "New".
Are you sure you want to remove it?
select q=quit y=yes n=no: y
Id 133 – New
Message code: 1966081
Thu May 05 00:25:27 PDT 2005
Node: 0 Severity: Degraded
Cage log event
cage2–A, loop 1:0:2, cage time Thu May 5 00:25:29 2005. Fan at position 1 is
running at high speed. Internal parameters: 0x0003 0x0109 01 01 00 00 00 00 00
00 00 00 00 00.
Alert 133 is marked as "New".
Are you sure you want to remove it?
select q=quit y=yes n=no: