22.17
InForm OS Version 2.2.4 Command Line Interface Reference
■ Model. The model can be DC2, DC3, or DC4.
■ Side. Specifies the right (1) or left (0) side of the drive cage.
Specifying the
–d option provides more detailed information about the drive cages. See the
following E-Class Storage Server example for
cage0:
cli% showcage -d
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
0 cage0 0:0:1 0 1:0:1 0 8 29-32 03 03 DC3 n/a
-----------Cage detail info for cage0 ---------
Position: ---
-----------Midplane Info------------
VendorId,ProductId 3PARdata,DC3
Serial_Num OPS45811C010719
Node_WWN 20000050CC010719
TempSensor_State OK
TempSensor_Value 35
OpsPanel_State OK
Audible_Alarm_State Muted
ID_Switch 4
Cage_State OK
Interface Board Info LoopA LoopB
Firmware_status Current Current
Product_Rev 03 03
IFC_State OK OK
ESH_State OK OK
Master_CPU Yes No
Loop_Map valid valid
Link_Speed 2Gbps 2Gbps
Port0_State OK OK
Port1_State No_SFP No_SFP
Port2_State No_SFP No_SFP
Port3_State No_SFP No_SFP
Power Supply Info State Fan State AC Model
ps0 OK MedSpeed OK --
ps1 OK MedSpeed OK --
-------------Drive Info------------- ----LoopA----- ----LoopB-----
Drive NodeWWN State Temp(C) ALPA LoopState ALPA LoopState
0:0 20000011c60b0379 OK 32 0x88 OK 0x88 OK
3:0 20000011c60b18b4 OK 29 0x81 OK 0x81 OK
4:0 2000000c50c3560d OK 31 0x80 OK 0x80 OK
7:0 2000000c501fd935 OK 30 0x79 OK 0x79 OK
8:0 2000000c501fd804 OK 32 0x76 OK 0x76 OK
11:0 20000011c60b0aeb OK 29 0x73 OK 0x73 OK
12:0 2000000c501fd7ad OK 32 0x72 OK 0x72 OK
15:0 2000000c501fcbe9 OK 31 0x6d OK 0x6d OK