Seagate ST3400071FC Betriebsanweisung Seite 232

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 718
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 231
15.12
Command Line Interface Reference InForm OS Version 2.2.4
–rw
Specifies that the display includes separate read and write data. If not specified, the total is
displayed.
–d <secs>
Specifies the interval in seconds that statistics are sampled from using an integer from 1
through
2147483. If no count is specified, the command defaults to 2 seconds.
–iter <number>
Specifies that the histogram is to stop after the indicated number of iterations using an
integer from
1 through 2147483647.
–sortcol <col> [,<dir>][:<col>[,<dir>]...]
Sorts command output based on column number <col>. Columns are numbered from left
to right, beginning with 0. You must specify a column number. In addition, you can specify
the direction of sorting
<dir> as follows:
inc
Sort in increasing order (default).
dec
Sort in decreasing order.
–filt <fspec>
Specifies that histograms below the threshold specified by the <fspec> argument are not
displayed. The
<fspec> argument is specified in the syntax of <op>,<val_ms>,<count>.
<op>
The <op> argument can be specified as one of the following:
r - Specifies read statistics.
w - Specifies write statistics.
t - Specifies total statistics.
rw - Specifies total read and write statistics.
<val_ms>
Specifies the threshold service time in milliseconds.
<count>
Specifies the minimum number of access above the threshold service time.
Seitenansicht 231
1 2 ... 227 228 229 230 231 232 233 234 235 236 237 ... 717 718