21.13
InForm OS Version 2.2.4 Command Line Interface Reference
–r
Specifies that the battery recharge time is reset and that 10 hours of charging time are
required for the battery to be fully charged.
SPECIFIERS
<node_ID>
Specifies the node number where the battery is installed.
<powersupply_ID>
Specifies the power supply number on the node using either 0 (left side from the rear of
the node) or
1 (right side from the rear of the node).
<battery_ID>
Specifies the battery number on the power supply where 0 is the first battery.
RESTRICTIONS
None.
EXAMPLES
The following example resets the battery test log and the recharging time for a newly installed
battery on node
2, power supply 1, and battery 0, with an expiration date of July 4, 2006:
NOTES
To view battery status information, issue the showbattery command. See page 22.8 for
information about the
showbattery command.
NOTE: The <powersupply_ID> and <battery_ID> specifiers can be obtained
from the output of the
showbattery command.
cli% setbattery -x 07/04/2006 2 1 0
Kommentare zu diesen Handbüchern