11.55
InForm OS Version 2.2.4 Command Line Interface Reference
EXAMPLES
The following example creates a virtual volume called vvr1. The –ha and –pol option values
are fixed. The RAID type can be changed when the virtual volume is created. Note that if
patterns are specified, it is not possible to mix read-only and read/write pattern specifications.
The command rejects the pattern.
NOTES
By default, logical disk are created using only physical disks with the same device type. (By
default, the Fibre Channel device type is used). Use the
–p devtype NL option to override
this default. Use
showpd –i to see the device types of physical disks in the system.
The value for –ssz and –rs can be set to . This can be used in conjunction with the
(default) read-only property for options to ensure that their value cannot be changed
when a virtual volume or logical disk or CPG is created and the system is used to set the
default values for these options.
cli$ createtemplate vv -ha mag -rw -t r1 -ro -pol stale_ss vvr1
cli$ createtemplate vv –ro –p –nd 0 –rw –p –mg 1,2 vpatt vvr1