Seagate ST3400071FC Betriebsanweisung Seite 505

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 718
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 504
22.99
InForm OS Version 2.2.4 Command Line Interface Reference
non_participate. Port is logically isolated from the Fibre Channel loop.
offline. The port is offline.
pending_reset. A reset of the port has been scheduled, but not yet completed.
Node_WWN. The WWN that belongs to the controller node identified in the N:S:P column.
Port_WWN/HW_Addr. The WWN that belongs to the controller node port identified in the
N:S:P
column.
Type. Indicates the port connection type.
host. Port is connected to hosts. This port can also be used for Remote Copy over IP
(RCIP).
disk. Port is connected to disks.
free. Port is not connected.
The following example displays hardware and connection information about the ports’ Fibre
Channel settings:
The following example displays all devices connected to each port and information about the
ports’ Fibre Channel settings:
The columns in the previous example are identified as follows:
N:S:P. The physical position of the port, in the syntax node:slot:port.
cli% showport -i
N:S:P Brand Model Rev Firmware Serial
1:2:1 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:2 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:3 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:4 3PAR FC044X 08 1.02.N.5 00981760001d6187
cli% showport -c
N:S:P Mode Device Pos Config Topology Rate Cls Mode_change
1:2:1 initiator cage4 0 valid private_loop 2Gbps 3 allowed
1:2:2 initiator cage5 0 valid private_loop 2Gbps 3 allowed
1:2:3 initiator cage7 0 valid private_loop 2Gbps 3 allowed
1:2:4 initiator cage6 0 valid private_loop 2Gbps 3 allowed
Seitenansicht 504
1 2 ... 500 501 502 503 504 505 506 507 508 509 510 ... 717 718

Kommentare zu diesen Handbüchern

Keine Kommentare