22.51
InForm OS Version 2.2.4 Command Line Interface Reference
EXAMPLES
The following example displays information for all system logical disks:
The columns in the previous example are identified as follows:
■ Id. The ID of the logical disk.
■ Name. The name of the logical disk.
■ Domain. The domain to which the logical disks belongs. If the domain does not exist, - is
displayed.
■ RAID. The RAID type (1 is for RAID 10 and 5 is for RAID 50).
■ State. The current status of the logical disk.
◆ normal. The logical disk has started and is available for use.
◆ orphan. Both the primary owner and backup owner nodes are down, and the logical
disk’s data is not available.
◆ preserved. Some disks used by the logical disk are missing. Data belonging to the
logical disk is saved on the preserved logical disk.
◆ stopped. The logical disk is stopped, and its data is not available.
cli% showld
Id Name RAID State Own SizeMB UsedMB Use Lgct LgId WThru MapV
0 log0.0 1 normal 0/- 20480 0 log 0 --- Y N
1 log1.0 1 normal 1/- 20480 0 log 0 --- Y N
2 pdsld0.0 1 normal 0/1 8192 0 P,F 0 --- Y N
3 admin.usr.0 1 normal 0/1 5120 5120 V 0 --- N Y
4 admin.usr.1 1 normal 1/0 5120 5120 V 0 --- N Y
5 VV111.usr.0 0 normal 0/1 256 256 V 0 --- N Y
6 VV111.usr.1 0 normal 1/0 256 256 V 0 --- N Y
7 Chevelle.usr.0 0 normal 0/1 256 256 C,V 0 --- N Y
8 tp-1-sa-0.0 1 normal 0/1 8192 256 C,SA 0 --- N Y
9 tp-1-sd-0.0 0 normal 0/1 32768 768 C,SD 0 --- N Y
10 442.usr.0 0 normal 0/1 256 256 V 0 --- N Y
11 tp-0-sa-0.0 1 normal 0/1 8192 256 C,SA 0 --- N Y
12 tp-0-sd-0.0 0 normal 0/1 32768 1024 C,SD 0 --- N Y
14 BVFullyProv.usr.0 0 normal 0/1 256 256 C,V 0 --- N Y
15 FullyProvCPVV.usr.0 0 normal 1/0 256 256 C,V 0 --- N Y
16 BVFullyProv.usr.1 0 normal 1/0 256 256 C,V 0 --- N Y
17 BaseVVFPfromCPG.usr.0 0 normal 0/1 1024 1024 C,V 0 --- N Y
18 BaseVVFPfromCPG.usr.1 0 normal 1/0 1024 1024 C,V 0 --- N Y
19 BaseVVFPfromCPGAdvan.usr.0 0 normal 0/1 1024 1024 C,V 0 --- N Y
20 BaseVVFPfromCPGAdvan.usr.1 0 normal 1/0 1024 1024 C,V 0 --- N Y
21 BVfromPDs.usr.0 0 normal 0/1 512 512 V 0 --- N Y
22 BVfromPDs.usr.1 0 normal 1/0 512 512 V 0 --- N Y
23 BVfromPDsAdvanced.usr.0 0 normal 0/1 512 512 V 0 --- N Y
24 BVfromPDsAdvanced.usr.1 0 normal 1/0 512 512 V 0 --- N Y
25 advancedbasevolume.usr.0 0 normal 0/1 1024 1024 C,V 0 --- N Y
26 advancedbasevolume.usr.1 0 normal 1/0 1024 1024 C,V 0 --- N Y
Kommentare zu diesen Handbüchern