10.12
Command Line Interface Reference InForm OS Version 2.2.4
rcip ping
Performs a ping from the specified interface to the specified address. Only for RCIP ports.
See Specifiers on page 10.14 for parameters required to issue this subcommand. Use with
the
–pf option to prevent fragmentation of packets (see Options on page 10.12).
rcfc init
Sets the specified Remote Copy interface(s) on the local port. Only for RCFC ports.
rcfc delete
Deletes the configuration for the Remote Copy interface on the local port.
intcoal
Enables or disables interrupt coalescing. See Specifiers on page 10.14 for parameters
required to issue this subcommand. Note that the specified port is reset.
OPTIONS
–m <mode>
This option can only be used with the rst subcommand. Resets the mode of the port. The
port can be reset into a
target or initiator mode. If not specified, the port is reset to
its current mode. If the port’s mode change value is prohibited, this command fails when
attempting to reset to a different mode. Use
showport –c to see whether mode change
is allowed or prohibited for a particular port. See notes at the bottom of this section for
additional information regarding port pair protection.
–l
Forces the port to reload firmware. This option can only be used with the rst subcommand
and cannot be used with the
-i option.
CAUTION: Use caution when changing modes for ports in LSI Fibre Channel
adapters. Changing the mode of one port in a pair (for example, from initiator to
target) causes the other port in the pair to also undergo a mode change. In the
case where one port in the pair is offline (and therefore a mode change can be
allowed), but the partner port is online, changing the mode of the offline port
causes the online partner port to undergo mode change as well. This results in
loss of use of the partner port because it is no longer online.