Seagate ST3400071FC Betriebsanweisung Seite 314

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 718
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 313
20.4
Command Line Interface Reference InForm OS Version 2.2.4
RESTRICTIONS
None.
EXAMPLES
The following example displays the commencement of Fibre Channel hot-plugging for drive
cage
cage0:
NOTES
Issuing the servicecage command results in chunklet relocation that causes a dip in
throughput.
The unstartfc subcommand is provided if a mistake was made when issuing the
servicecage command. The unstartfc subcommand stops the original command.
After issuing the startfc or unstartfc subcommands, the endfc subcommand must be
issued to indicate that service is completed and to restore the drive cage to its normal state.
cli% servicecage startfc –f -ovrd cage0