Troubleshooting operational problems 17-21
Voice card/channel problems
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Channel status Idle
but cannot be
acquired
When the channel status is Idle but cannot be acquired,
follow these steps.
Step Action
1 Check the status of the channels.
2 Check the SEER printout for messages related to that channel.
3 Take the appropriate action for that SEER.
4 Disable or reenable the channel on the Meridian 1.
5 Verify that the network cable is connected to the assigned port.
6 Verify that the VASID in the Meridian 1 configuration record
matches the VASID in the main Meridian Mail ACD Queue.
7 Verify that the data entry for the VSDN table and Channel
Allocation Table is correct.
Note:
If these procedures are unsuccessful, record detailed
information and contact your Nortel Networks support
organization.