12-24 Configuring the Meridian 1
Configuring the trunk route data block (NMS only)
Standard 1.0 Modular Option EC Installation and Maintenance Guide November 1999
Configuring the trunk route data block (NMS only)
Introduction
This procedure shows how to configure the trunk route data
block for the Network Message Service feature.
Note: Ensure that Digit Manipulation (DMI in Overlay 86) is
not used to insert ESN access codes at the sending switch. You
must do the ESN access code insertion at the receiving switch
(INAC in Overlay 16).
Configuring the route
data block
To configure the route data block, follow these steps.
Overlay 16—Route data block parameters
Step Action
1 Load Overlay 16 at the Meridian 1 administration terminal.
2 Respond to the prompts as shown in the following table.
3 When configuration is complete, reply END to the prompt REQ.
Prompts Responses Description
REQ Either NEW or CHG
TYPE RDB Route data block
CUST Meridian 1 customer number
ROUTE Route number
PNI Customer Private Network ID of the
non-local target Meridian 1
NCRD YES Network call redirection provides
the CLID display information.
TRO YES Optimize trunk usage on this route.
INAC YES Insert ESN access code to
incoming private network call.
CR Press <Return> to the end of the
overlay. (The prompt REQ comes
up.)
**** Exits the overlay.