Starting up and configuring Meridian Mail 13-23
Checking out Meridian Mail
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
10 Check the status of each DSP to make sure they are
all functional. Press the [DSP Port Status] softkey.
Result: DSP Port Status should be idle for all ports.
Note: For a full description of this screen, see the
System Administration Guide
(NTP 555-7001-301).
This document also describes how to run out-of-
service diagnostics for ports that do not come to idle
status on startup or to active status during the testing
described in steps 14 to 16.
11 While watching the DSP port status screen, dial the
voice messaging DN from a phone connected to the
switch.
12 Note which channels become active.
13 Ensure there is no noise on the line.
14 Release, and repeat steps 11 to 13 until all ports
have been tested.
15 If all appears to be OK, press the [Exit] softkey to
return to the Logon screen.
16 Install and close the cover on the EC 11 cabinet.
CAUTION
Risk of equipment damage
To reduce stress on the system, use the reset
button on the faceplate of the Enhanced
MMP40 or MMP40 card to restart the system
instead of powering the cabinet off and on.
Reset node 1 first, then node 2 in sequence,
as applicable.
However, if there is a question regarding the
state of the system after the system reset,
power off the system, wait 10 seconds, then
power it back on to restart.