Installing the EC 11 to Meridian 1 Option 11 switch interface 9-7
Determining the number of MGate cards needed
Standard 1.0 Option 11 EC Installation and Maintenance Guide November 1999
The following table shows the hardware needed to connect
the main cabinet of an Option 11 switch to an EC 11.
Note: Use only specific card slots on the Meridian 1 Option
11 switch to house the MGate cards. All MGate cards must
be in the same cabinet. For details, see “Installing the
network loop cables” on page 9-11.
Number
of voice
channels
Number of
MGate cards in
main cabinet of
Option 11 switch
Number
of NLI
cables
Utility card
port(s) in EC 11
16 1 (slot 2) 1 1 (Node 1 -
NLI1)
32 2 (slot 2, 6) 2 2 (Node 1 - NLI1
and NLI2)
48 3 (slot 2, 6, 10) 3 3 (Node 1 - NLI1
and NLI2, Node
2 - NLI3)
CAUTION
Risk of interruption to service
Meridian 1 cards are hot-pluggable.
However, to remove or install a card, you
must disable it first in the software.