Chapter 2, Hardware Configuration 37
Hardware Verification
target and lun allocations (refer to step 2 on page 33)
extended copy software support (for the third-party copy feature; refer to the
documentation that came with the router/bridge)
IP address setting of the router/bridge, if it supports a telnet connection (refer to
the documentation that came with the device)
5. Check the following on the switch:
The port types (for example, loop vs. fabric)
IP address setting of the switch, if it supports a telnet connection (refer to the
documentation that came with the switch)
6. Perform the configuration of the host bus adapters and confirm that the operating
system recognizes the luns by performing a reconfiguration reboot to create the
device files (step 13 and step 14 in the previous procedure).
7. After installing NetBackup 4.0V and ServerFree Agent software, perform an sgscan.
Check for proper output and recognition of devices.
Here is sample output from sgscan:
barney# sgscan
/dev/sg/c0t6l1: Disk (/dev/rdsk/c1t6d1): "SEAGATE ST39175LW"
/dev/sg/c0t6l4: Tape (/dev/rmt/2): "QUANTUM DLT7000"
/dev/sg/c0t6l5: Changer: "HP C6280-7000"
8. Use the following commands to verify the functionality of all of the SAN equipment
at a system level:
For tape drives:
mt -f /dev/rmt/device_name status
For disk drives:
prtvtoc /dev/rdsk/* | more
9. Once the equipment has been discovered, set the addresses to FIXED at the
router/bridge so that they will not change when the equipment is reset.