14 R/Evolution 2730 Release Notes for Software Version J200R05 October 2007
Your installation package contents included a micro-DB9-to-DB9 serial cable. If
necessary, use a DB9-to-DB25 adapter (not included) for connecting the serial cable
to a DB25 serial port on the host computer.
3. Start and configure a terminal emulator, such as HyperTerminal or VT-100, using
the display settings in Table 1 and the connection settings in Table 2.
Table 1 Terminal Emulator Display Settings
Parameter Value
Terminal Emulation Mode VT-100 or ANSI (for color support)
Font Terminal
Translations None
Columns 80
Table 2 Terminal Emulator Connection Settings
Parameter Value
Connector COM1 (typically)
Baud rate (bits/sec) 115,200
Data bits 8
Parity None
Stop bits 1
Flow control None