Seitenansicht 39
40
Start
Is Disk
Replaced
Check Disk is Okay
Is Disk Okay ?
Check Data on Disk (use fstyp(1M))
Data on Disk ?
Get the VG name to
which the PV belongs to
Is VG Active ?
Check and collect Config info for VG
Is Good Config
exists ?
The Disk is not
seen with
ioscan(1M) output
or not readable.
Correct and restart
Yes
YesNoYes
End
No
The disk appears to have
some data or the disk
belongs to some volume
manager. Please replace the
correct disk with an unused
and restart
Activate the VG
and Restart
No
Couldn’t find the configuration. Ensure
prior to restarting, below information is
available.
- pvdisplay PV info
- Lvdisplay for each lvol on PV info
- /etc/lvmconf/<vg_name>.conf is
accessible
End
No
Yes
Check root
Disk
Gather all required information
Eg :
- What PV is to be replaced
-Is the PV Hot swappable
-What LV’s are affected
- What their layout ? Are they mirrored
- Is the PV root Disk or part of root VG
- Note down the ioscan -m lun <dsf> output
Hot Swappable ?
Yes
Shutdown the system, Turnoff
the power, Replace the disk
and Restart
Any unmirrored logical
Volumes?
Try to close all affected LVs
- halt applications
- fuser -cu /mnt
- ps -f ppids
- fuser -ku /mnt
- umount /mnt
Yes
Successfully
Disabled ?
Pvchange -a N PV
Replace the disk
Check Root
Disk
Yes
Yes
Notify the mass storage subsytem that the
disk is replaced by running the command
scsimgr replace_wwid -D <dsf>
Determine the new LUN instance number
for the replacement disk with command
ioscan -m lun
Assign the old LUN instance number to the
replacement disk using the command
io_redirect_dsf -d <old dsf> -n <new dsf>
Verify using the command
ioscan -m lun <old dsf>
Disk
Replaced
Disk
Replaced
Yes
No
No
No
No
Seitenansicht 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 66 67