Preventing Possible System Problems
Preventing Possible System Problems
When system memory is limited, Solaris unloads unused drivers from memory and
reloads drivers as needed. Tape drivers are a frequent candidate for unloading, since they
tend to be less heavily used than disk drivers. Depending on the timing of these unload
and load events for the st (Sun), sg (VERITAS), and fibre channel drivers, various
problems may result. These problems can range from devices “disappearing” from a SCSI
bus to system panics.
VERITAS recommends adding the following forceload statements to the
/etc/system file. These statements prevent the st and sg drivers from being unloaded
from memory.
forceload: drv/st
forceload: drv/sg
Other statements may be necessary for various fibre channel drivers, such as the
following example for JNI drivers. This statement prevents the named driver from being
unloaded from memory.
forceload: drv/fcaw
Understanding the SCSI Passthru Drivers
NetBackup Media Manager provides its own driver for communicating with
SCSI-controlled robotic peripherals. This driver is called the SCSA (Generic SCSI passthru
driver), also referred to as the sg driver.
Note Since NetBackup uses its own passthru driver, the Solaris sgen scsi passthru driver
is not supported.
The SCSI passthru driver and SCSI passthru device paths are required by NetBackup for
full feature support. Performance will be degraded if SCSI passthru is not provided. The
passthru driver is used
By avrd and robotic processes to scan drives.
By NetBackup and Storage Migrator for locate-block positioning.
By NetBackup and Storage Migrator for SAN error recovery.
By NetBackup and Storage Migrator for Quantum SDLT performance optimization.
By NetBackup and Storage Migrator for SCSI reserve/release.
To set the optical drive type (as explained in “Setting the HP Optical Drive Type in
Nonvolatile Memory” on page 25).
By the NetBackup device configuration GUIs to collect robot and drive information.