. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST310014ACE. . . . . . . . . . . . . . . . . . . . . . . . .
2 ST310014ACE Product Manual, Rev. DSpecification summary tableThe specifications listed in this table are for quick reference. For details on specif
ST310014ACE Product Manual, Rev. D 3 Standby to ready (sec typical) 6.5 secSpindown (sec typical) 10 secStartup current (typical) 0.9 amps (5V), 1.9 a
4 ST310014ACE Product Manual, Rev. D1.0 Drive specificationsUnless otherwise noted, all specifications are measured under ambient conditions, at 25°
ST310014ACE Product Manual, Rev. D 5 1.4 Physical characteristics1.5 Start/stop times1.6 Seek timesSeek measurements are taken with nominal power a
6 ST310014ACE Product Manual, Rev. DNote. These drives are designed to meet the seek times represented in this manual consistently. Physical seeks, r
ST310014ACE Product Manual, Rev. D 7 not spinning, and the servo and read/write electronics are in power-down mode.Typical current profileFigure 1. Ty
8 ST310014ACE Product Manual, Rev. D1.7.2 Conducted noiseInput noise ripple is measured at the host system power supply across an equivalent 80-ohm
ST310014ACE Product Manual, Rev. D 9 established using a Standby or Idle command. In Standby mode, thedrive buffer is enabled, the heads are parked an
10 ST310014ACE Product Manual, Rev. D1.8.3 Humidity1.8.3.1 Relative Humidity1.8.3.2 Wet bulb temperature1.8.4 Altitude1.8.5 ShockAll shock spe
ST310014ACE Product Manual, Rev. D 11 1.8.6.1 Operating vibrationThe following table lists the maximum vibration levels that the drive may expe-rien
12 ST310014ACE Product Manual, Rev. D1.10 Electromagnetic immunityWhen properly installed in a representative host system, the drive operates withou
ST310014ACE Product Manual, Rev. D 13 1.12.2 Electromagnetic compatibilityHard drives that display the CE mark comply with the European Union (EU) re
14 ST310014ACE Product Manual, Rev. DAustralian C-Tick (N176)If this drive has the C-Tick marking, it complies with the Australia/New Zealand Standar
ST310014ACE Product Manual, Rev. D 15 2.0 Configuring and mounting the driveThis section contains the specifications and instructions for configuring
16 ST310014ACE Product Manual, Rev. D2.2 Breather filter hole precautionsThis section contains information regarding the precautions which should be
ST310014ACE Product Manual, Rev. D 17 2.3 Jumper settings2.3.1 Master/slave configurationThe options jumper block shown in Figure 2 is used to confi
18 ST310014ACE Product Manual, Rev. D2.3.2 Cable-select optionComputers that use cable-select determine the master and slave drives by selecting or
ST310014ACE Product Manual, Rev. D 19 2.1 Drive mountingYou can mount the drive in any orientation using four screws in the side-mounting holes or fo
20 ST310014ACE Product Manual, Rev. D3.0 ATA interface These drives use the industry-standard ATA task file interface that supports 16-bit data tran
ST310014ACE Product Manual, Rev. D 21 Figure 5. I/O pins and supported ATA signalsReset–GroundDD7DD8DD6DD9DD5DD10DD4DD11DD3DD12DD2DD13DD1DD14DD0DD15Gr
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST310014ACE. . . . . . . . . . . . . . . . . . . . . . . . .
22 ST310014ACE Product Manual, Rev. D3.1.1 Supported ATA commandsThe following table lists ATA-standard commands that the drive sup-ports. For a det
ST310014ACE Product Manual, Rev. D 23 3.1.2 Identify Drive commandThe Identify Drive command (command code ECH) transfers information about the drive
24 ST310014ACE Product Manual, Rev. DWord Description Value0 Configuration information: • Bit 15: 0 = ATA; 1 = ATAPI • Bit 7: removable media • Bit 6
ST310014ACE Product Manual, Rev. D 25 50 Device-specific standby timer value0000H51 PIO data-transfer cycle timing mode 0200H52 Retired 0200H53 Words
26 ST310014ACE Product Manual, Rev. D66 Recommended multiword DMA transfer cycle time per word (120 nsec)0078H67 Minimum PIO cycle time without IORDY
ST310014ACE Product Manual, Rev. D 27 92 Master Password Revision codeFFFEH93 Hardware Reset Value (see description following this table)xxxxH94 Auto
28 ST310014ACE Product Manual, Rev. D3.1.3 Set Features commandThis command controls the implementation of various features that the drive supports.
ST310014ACE Product Manual, Rev. D 29 Note. At power-on, or after a hardware or software reset, the default values of the features are as indicated ab
30 ST310014ACE Product Manual, Rev. D3.1.4 S.M.A.R.T. commandsS.M.A.R.T. provides near-term failure prediction for disc drives. When S.M.A.R.T. is e
2002, 2003 Seagate Technology LLC All rights reservedPublication Number: 100216026, Rev. D, December, 2003Seagate, Seagate Technology and the Seaga
Seagate Technology LLC920 Disc Drive, Scotts Valley, California 95066-4544, USAPublication Number: 100216026, Rev. D, Printed in USA
ST310014ACE Product Manual, Rev. D iiiContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1S
iv ST310014ACE Product Manual, Rev. D1.12.3 FCC verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.0 Configuring and moun
ST310014ACE Product Manual, Rev. D vFiguresFigure 1. Typical startup and operation current profile . . . . . . . . . . . . 7Figure 2. Breather filter
vi ST310014ACE Product Manual, Rev. D
ST310014ACE Product Manual, Rev. D 1 IntroductionThis manual describes the functional, mechanical and interface specifi-cations for the ST310014ACE. T
Kommentare zu diesen Handbüchern