38 Elite 23 Product Manual, Rev. A
8.4 Drive mounting
No special drive mechanical mounting constraints are applicable to this drive.
8.5 Grounding
Signal ground (PCB) and HDA ground are connected together in the drive and cannot be separated by the
user. The equipment in which the drive is mounted is connected directly to the HDA and PCB with no electri-
cally-isolating shock mounts. If you do not want the system chassis to be connected to the HDA/PCB ground,
you must provide a nonconductive (electrically-isolating) method of mounting the drive in the host equipment.
Increased radiated emissions may result if you do not provide the maximum surface area ground connection
between system ground and drive ground. This is the system designer’s and integrator’s responsibility.