12 SVA Path User’s Guide
Command options that take arguments (shown in braces after the
command) require an argument and should not be run without one.
Table 3-1 setsp Command Options
Option Effect
-a
show current device configuration and state
-b{0|1}
set load balancing for a logical drive. (pages
24 and 27).
-b0 disables load balancing for the device;
-b1 enables it
Must be used with
-l
-d<n>
set a retry delay of n for a logical drive,
where n is the interval between retries in
milliseconds (page 24 and 27)
-e{0|1}
set exclusion for a logical drive (pages 24
and 26).
-e0 includes the device;
-e1 excludes it;
excluded devices are not accessible by user
applications;
devices are excluded by default
Must be used with
-l
-f{0|1}
set failback for a logical drive.
-f0 disables failback for the device;
-f1 enables it (pages 25 and 28)
Must be used with
-l
-g
generate configuration files after an sppath
command (Page 21)
-i
show contents of driver configuration files
Seitenansicht 21