22.11
InForm OS Version 2.2.4 Command Line Interface Reference
■ Node. The controller node number.
■ PS. The power supply number.
■ Bat. The battery ID.
■ Test. The current status of the battery.
■ Result. The battery status, shows as passed or failed.
■ Dur(mins). Indicates the length of time for the results to return.
■ Time. Indicates the time of the last battery test.
NOTES
■ Battery information is set by issuing the setbattery command. See setbattery on
page 21.12 for more information.
■ For the E-Class storage servers, the Power Supply 0's primary node is 0 and its secondary
node is 1. The Power Supply 1's primary node is 1 and its secondary node is 0. The primary
node can read and modify the power supply's properties. The secondary node can only read
the power supply's properties. Therefore, for the E-Class, with the -old option, the battery
information for Node 0 Power Supply 0 is the same as the battery information for Node 1
Power Supply 0. The battery information for Node 1 Power Supply 1 is the same as the
battery information for Node 0 Power Supply 1.