Seitenansicht 11
Chapter 1: HP Clustered File System Commands 6
Copyright © 1999-2005 PolyServe, Inc. All rights reserved.
-n max-nodes
The maximum number of nodes that can be in the cluster.
-l label
The label to be applied to the filesystem.
mx – HP Clustered File System command-line
interface
The mx utility provides a command-line interface for administering a
cluster and monitoring its operation. See Chapter 2 for more information
about the commands provided with this utility.
mxcheck – verify HP Clustered File System
requirements
Synopsis
/opt/hpcfs/bin/mxcheck
Description
The mxcheck utility verifies that a server meets the configuration
requirements for HP Clustered File System. It is run automatically each
time HP Clustered File System is started. Output from the utility appears
on the screen and is also written to the /var/hpcfs/mxcheck directory. If you
are experiencing errors, check the messages in this directory.
The mxcheck utility performs checks such as the following: operating
system version and configuration; available physical memory and disk
space; HBA driver versions; FibreChannel switch versions; network
addresses. The utility also attempts to access gateways and FC switches.
mxcollect – collect configuration information
Synopsis
/opt/hpcfs/tools/mxcollect
Description
This script collects configuration information and log files from the
cluster. The script is typically run under the direction of HP Technical
Support.