Seagate Barracuda 9FC Handbuch

Stöbern Sie online oder laden Sie Handbuch nach Interne Festplatten Seagate Barracuda 9FC herunter. Seagate Barracuda 9FC Product manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 94
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Product Manual
Cheetah 15K.6 FC
100465943
Rev. A
October 2007
ST3450856FC
ST3300656FC
ST3146356FC
Seitenansicht 0
1 2 3 4 5 6 ... 93 94

Inhaltsverzeichnis

Seite 1 - Cheetah 15K.6 FC

Product ManualCheetah 15K.6 FC100465943Rev. AOctober 2007ST3450856FCST3300656FCST3146356FC

Seite 2

2Cheetah 15K.6 FC Product Manual, Rev. A

Seite 3 - Contents

Cheetah 15K.6 FC Product Manual, Rev. A32.0 Applicable standards and reference documentationThe drive has been developed as a system peripheral to the

Seite 4

4Cheetah 15K.6 FC Product Manual, Rev. A2.1.2 Electromagnetic complianceSeagate uses an independent laboratory to confirm compliance with the directiv

Seite 5

Cheetah 15K.6 FC Product Manual, Rev. A5Seagate also has internal systems in place to ensure ongoing compliance with the RoHS Directive and all laws a

Seite 6

6Cheetah 15K.6 FC Product Manual, Rev. A

Seite 7 - List of Figures

Cheetah 15K.6 FC Product Manual, Rev. A73.0 General descriptionCheetah 15K.6 FC drives provide high performance, high capacity data storage for a vari

Seite 8

8Cheetah 15K.6 FC Product Manual, Rev. A3.1 Standard featuresCheetah 15K.6 FC drives have the following standard features:• Perpendicular recording te

Seite 9 - 1.0 Scope

Cheetah 15K.6 FC Product Manual, Rev. A93.3 Performance• Programmable multi-segmentable cache buffer • 800 Mbytes/sec maximum instantaneous data trans

Seite 10

10Cheetah 15K.6 FC Product Manual, Rev. A• Single-unit shipping pack. The drive is normally shipped in bulk packaging to provide maximum protection ag

Seite 11 - 2.1 Standards

Cheetah 15K.6 FC Product Manual, Rev. A114.0 Performance characteristicsThis section provides detailed information concerning performance-related char

Seite 12

©2007, Seagate Technology LLC All rights reserved. Publication number: 100465943, Rev. A October 2007Seagate, Seagate Technology and the Wave logo a

Seite 13 - 2.3 Reference documents

12Cheetah 15K.6 FC Product Manual, Rev. A4.2.2 Format command execution time (minutes) 4.2.3 General performance characteristics 4.3 Start/stop time

Seite 14

Cheetah 15K.6 FC Product Manual, Rev. A13the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint

Seite 15 - 3.0 General description

14Cheetah 15K.6 FC Product Manual, Rev. AIf the number of write data logical blocks exceed the size of the segment being written into, when the end of

Seite 16 - 3.2 Media description

Cheetah 15K.6 FC Product Manual, Rev. A155.0 Reliability specificationsThe following reliability specifications assume correct host and drive operatio

Seite 17 - 3.5 Formatted capacities

16Cheetah 15K.6 FC Product Manual, Rev. A5.1.3 Seek errorsA seek error is defined as a failure of the drive to position the heads to the addressed tra

Seite 18

Cheetah 15K.6 FC Product Manual, Rev. A17The Pass-through state is disabled while the drive performs self test of the FC interface. The control line f

Seite 19

18Cheetah 15K.6 FC Product Manual, Rev. AReporting controlReporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (

Seite 20 - 4.3 Start/stop time

Cheetah 15K.6 FC Product Manual, Rev. A19be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any valu

Seite 21 - 4.5 Cache operation

20Cheetah 15K.6 FC Product Manual, Rev. A• Motor will not spin• Motor will not lock to speed• Servo will not lock on track• Drive cannot read configur

Seite 22

Cheetah 15K.6 FC Product Manual, Rev. A21The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. T

Seite 23 - 5.1 Error rates

Cheetah 15K.6 FC Product Manual, Rev. AiContents1.0 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 24 - 5.2 Reliability and service

22Cheetah 15K.6 FC Product Manual, Rev. A

Seite 25 - 163 milliseconds

Cheetah 15K.6 FC Product Manual, Rev. A236.0 Physical/electrical specificationsThis section provides information relating to the physical and electric

Seite 26

24Cheetah 15K.6 FC Product Manual, Rev. A [1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val-ue

Seite 27

Cheetah 15K.6 FC Product Manual, Rev. A25347 I/Os per second for ST3300656FC and ST3146356FC models. Current and power specified at nomi-nal voltages.

Seite 28

26Cheetah 15K.6 FC Product Manual, Rev. A Figure 1. Typical ST3450856FC current profiles

Seite 29

Cheetah 15K.6 FC Product Manual, Rev. A27 Figure 2. Typical ST3300656FC current profiles

Seite 30

28Cheetah 15K.6 FC Product Manual, Rev. A Figure 3. Typical ST3146356FC current profiles

Seite 31 - 6.2 DC power requirements

Cheetah 15K.6 FC Product Manual, Rev. A296.3 Power dissipationST3450856FCTypical power dissipation under idle conditions in 4 Gbit operation is 12.27

Seite 32

30Cheetah 15K.6 FC Product Manual, Rev. AST3300656FCTypical power dissipation under idle conditions in 4 Gbit operation is 10.69 watts (36.5 BTUs per

Seite 33

Cheetah 15K.6 FC Product Manual, Rev. A31ST3146356FCTypical power dissipation under idle conditions in 4 Gbit operation is 9.56 watts (32.6 BTUs per h

Seite 34

iiCheetah 15K.6 FC Product Manual, Rev. A6.4.2 Relative humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 35

32Cheetah 15K.6 FC Product Manual, Rev. Ab. Non-operating–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour.

Seite 36

Cheetah 15K.6 FC Product Manual, Rev. A33b. Operating—abnormalEquipment, as installed for normal operation, does not incur physical damage while subje

Seite 37 - 6.3 Power dissipation

34Cheetah 15K.6 FC Product Manual, Rev. A Figure 8. Recommended mountingZYXZYX

Seite 38

Cheetah 15K.6 FC Product Manual, Rev. A356.4.4.2 Vibrationa. Operating—normalThe drive as installed for normal operation, shall comply with the comple

Seite 39 - 6.4 Environmental limits

36Cheetah 15K.6 FC Product Manual, Rev. AUsers should use caution exposing any electronic components to uncontrolled chemical pollutants and corro-siv

Seite 40 - DA Temp

Cheetah 15K.6 FC Product Manual, Rev. A376.5 Mechanical specificationsThe following nominal dimensions are exclusive of the decorative front panel acc

Seite 41

38Cheetah 15K.6 FC Product Manual, Rev. A

Seite 42

Cheetah 15K.6 FC Product Manual, Rev. A397.0 Defect and error management Seagate continues to use innovative technologies to manage defects and errors

Seite 43

40Cheetah 15K.6 FC Product Manual, Rev. AThe drive firmware error recovery algorithms consists of 13 levels for read recoveries and five levels for wr

Seite 44

Cheetah 15K.6 FC Product Manual, Rev. A41[1] These values are subject to change. Setting these retry counts to a value below the default setting coul

Seite 45 - 6.5 Mechanical specifications

Cheetah 15K.6 FC Product Manual, Rev. Aiii9.6 Signal characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 46

42Cheetah 15K.6 FC Product Manual, Rev. Aservice by the host system. On regular duty drives, if the host system makes use of the BMS Log Page, it can

Seite 47

Cheetah 15K.6 FC Product Manual, Rev. A437.7 Idle Read After WriteIdle Read After Write (IRAW) utilizes idle time to verify the integrity of recently

Seite 48

44Cheetah 15K.6 FC Product Manual, Rev. A

Seite 49 - 7.4 Background Media Scan

Cheetah 15K.6 FC Product Manual, Rev. A458.0 InstallationCheetah 15K.6 FC disc drive installation is a plug-and-play process. There are no jumpers, sw

Seite 50 - 7.5 Media Pre-Scan

46Cheetah 15K.6 FC Product Manual, Rev. AIf forced air is necessary, possible air-flow patterns are shown in Figure 10. The air-flow patterns are crea

Seite 51 - 7.7 Idle Read After Write

Cheetah 15K.6 FC Product Manual, Rev. A478.5 GroundingSignal ground (PCBA) and HDA ground are connected together in the drive and cannot be separated

Seite 52

48Cheetah 15K.6 FC Product Manual, Rev. A

Seite 53 - 8.0 Installation

Cheetah 15K.6 FC Product Manual, Rev. A499.0 Interface requirements This section partially describes the interface requirements as implemented on Chee

Seite 54 - 8.4 Drive mounting

50Cheetah 15K.6 FC Product Manual, Rev. A9.1.2 Fibre Channel task management functionsTable 7 lists the Fibre Channel SCSI Fibre Channel Protocol (FC

Seite 55 - 8.5 Grounding

Cheetah 15K.6 FC Product Manual, Rev. A519.1.4 Fibre Channel port loginTable 9 identifies the required content of the N_Port Login (PLOGI) payload fro

Seite 56

ivCheetah 15K.6 FC Product Manual, Rev. A

Seite 57 - 9.0 Interface requirements

52Cheetah 15K.6 FC Product Manual, Rev. A9.1.5 Fibre Channel port login acceptTable 10 identifies the N_Port Login access payload values.9.1.6 Fibre C

Seite 58

Cheetah 15K.6 FC Product Manual, Rev. A539.1.7 Fibre Channel Process Login AcceptTable 12 lists Cheetah 15K.6 FC process login accept payload data.9.1

Seite 59 - Must = 1

54Cheetah 15K.6 FC Product Manual, Rev. A9.1.9 Fibre Channel fabric accept loginTable 14 lists the required content of the Fabric Login Accept (ACC) p

Seite 60

Cheetah 15K.6 FC Product Manual, Rev. A559.1.10 Fibre Channel Arbitrated Loop optionsTable 15 lists the FC-AL options supported by Cheetah 15K.6 FC dr

Seite 61

56Cheetah 15K.6 FC Product Manual, Rev. A9.3 SCSI commands supported Table 16 lists the SCSI commands supported by Cheetah 15K.6 FC drives. Tab

Seite 62

Cheetah 15K.6 FC Product Manual, Rev. A57Y Verify error recovery page (07h) Y Caching parameters page (08h) Y Control mode page (0Ah)Y Fibre Channel I

Seite 63 - 9.2 Dual port support

58Cheetah 15K.6 FC Product Manual, Rev. A32h N Search data low 33h N Set limits 34h N Prefetch 35h Y Synchronize cache 36h N Lock-unlock-cache 37h Y R

Seite 64 - 9.3 SCSI commands supported

Cheetah 15K.6 FC Product Manual, Rev. A59[1] Cheetah 15K.6 FC drives can format to 512, 520, 524 or 528 bytes per logical block.[2] Warning. Power los

Seite 65

60Cheetah 15K.6 FC Product Manual, Rev. A9.3.1 Inquiry data Table 17 lists the Inquiry command data that the drive should return to the initiator per

Seite 66

Cheetah 15K.6 FC Product Manual, Rev. A61On standard OEM drives, the saved values are taken from the default values list and stored into the saved val

Seite 67

Cheetah 15K.6 FC Product Manual, Rev. AvList of FiguresFigure 1. Typical ST3300656FC current profiles . . . . . . . . . . . . . . . . . . . . . . . .

Seite 68

62Cheetah 15K.6 FC Product Manual, Rev. ATable 18: Mode Sense data saved, default and changeable values for ST3450856FC drives MODE DATA HEADER:00 be

Seite 69

Cheetah 15K.6 FC Product Manual, Rev. A63Table 19: Mode Sense data default and changeable values for ST3300656FC drives MODE DATA HEADER:00 be 00 10 0

Seite 70

64Cheetah 15K.6 FC Product Manual, Rev. ATable 20: Mode Sense data default and changeable values for ST3146356FC drives MODE DATA HEADER: 00 be 00 10

Seite 71

Cheetah 15K.6 FC Product Manual, Rev. A659.4 Miscellaneous operating features and conditions Table 21 lists various features and conditions. A “Y” in

Seite 72

66Cheetah 15K.6 FC Product Manual, Rev. A9.5 FC-AL physical interface Figure 11 shows the location of the J1 Fibre Channel single connection attachmen

Seite 73

Cheetah 15K.6 FC Product Manual, Rev. A679.5.2 Connector requirements The FC-AL SCA device connector is illustrated in Figure 13. Figure 13. FC-AL

Seite 74 - 9.5 FC-AL physical interface

68Cheetah 15K.6 FC Product Manual, Rev. ATable 24: FC-SCA pin descriptions *Short pins in mating backpanel connector.[1] This pin may be connected to

Seite 75

Cheetah 15K.6 FC Product Manual, Rev. A699.5.6 PowerPower is supplied through the FC-SCA with support for +5 volts and +12 volts. All of the voltage p

Seite 76

70Cheetah 15K.6 FC Product Manual, Rev. A9.5.8 Active LED OutThe Active LED Out signal is driven by the drive as indicated in Table 25.The Active LED

Seite 77

Cheetah 15K.6 FC Product Manual, Rev. A719.5.11 SEL_6 through SEL_0 ID linesThe SEL_6 through SEL_0 ID lines determine drive address, and, optionally,

Seite 79

72Cheetah 15K.6 FC Product Manual, Rev. ATable 27: Arbitrated loop physical address (AL_PA) valuesAL_PA (hex)SEL ID (hex)Setting (dec)AL_PA (hex)SEL I

Seite 80

Cheetah 15K.6 FC Product Manual, Rev. A739.5.12 Device control codesThe drive inputs a Device Control Code on the DEV_CTRL_CODE lines at power up to d

Seite 81 - 9.6 Signal characteristics

74Cheetah 15K.6 FC Product Manual, Rev. A9.6.2 LED driver signalsFault and Active LED signals are located in the FC-SCA connector (J1). See Table 30 f

Seite 82 - XMIT Eye

Cheetah 15K.6 FC Product Manual, Rev. A75Figure 16 provides the data valid eye diagram for typical and minimum requirements to recover data at the spe

Seite 83 - Vin (mv)

76Cheetah 15K.6 FC Product Manual, Rev. A

Seite 84

Cheetah 15K.6 FC Product Manual, Rev. A7710.0 Seagate Technology support servicesInternetFor information regarding Seagate products and services, visi

Seite 85 - Seagate Service Centers

78Cheetah 15K.6 FC Product Manual, Rev. ACustomer Service OperationsWarranty ServiceSeagate offers worldwide customer support for Seagate products. Se

Seite 86 - Asia/Pacific Support Services

Cheetah 15K.6 FC Product Manual, Rev. A79IndexNumerics12 voltpins 693rd party reserve command 595 volt pins 69AAbort Sequence (ABTS) 49abort t

Seite 87 - Numerics

80Cheetah 15K.6 FC Product Manual, Rev. ADDAR 42data headsread/write 11data rateinternal 11data transfer rate 12data valid eye 75Date code p

Seite 88

Cheetah 15K.6 FC Product Manual, Rev. A81flawed sector reallocation 8FLOGIreceived on Port A 53received on Port B 53Force unit access command

Seite 89

Cheetah 15K.6 FC Product Manual, Rev. A11.0 ScopeThis manual describes Seagate Technology® LLC, Cheetah® 15K.6 FC (Fibre Channel) disc drives.Cheetah

Seite 90

82Cheetah 15K.6 FC Product Manual, Rev. AReporting actual retry count 65Segmented caching 65SMP = 1 in Mode Select command 65Synchronized (locke

Seite 91 - 51, 54

Cheetah 15K.6 FC Product Manual, Rev. A83Prefetch command 58prefetch/multi-segmented cache control 12preventive maintenance 15private loopFC-AL

Seite 92

84Cheetah 15K.6 FC Product Manual, Rev. Asingle-unit shipping pack kit 10SMART 9, 17SMP = 1 in Mode Select command 65SO 51, 54spindle brak

Seite 94 - Seagate Technology LLC

Seagate Technology LLC920 Disc Drive, Scotts Valley, California 95066-4544, USAPublication Number: 100465943, Rev. A, Printed in USA

Kommentare zu diesen Handbüchern