3/11/02 Silkworm 12000 Version 4.0 Zoning with Bloom Self Paced Training By : Todd Einck
Zoning with WEB TOOLS Highlights Brocade recommends that when zoning a Fabric that contains a SilkWorm 12000 through Web Tools that it is done while
When using WEB TOOLS for Zoning, the one major change is how a port is selected on the SW12000. To select the appropriate port, it is now necessary t
WEB TOOLS Zoning and RSCN’s After configuring all the alias, zone, and configuration objects, it is still necessary to save and activate them. Usi
When you click ‘Ok’ or “Apply” with the “Save Config” radio box checked under the “Config” tab , the changes will be saved to the ‘Defined” configura
Another point worth mentioning is that if another user changes the zoning while WEB TOOLS Zoning is open, the “Ref Zone” button will begin to flash r
QuickLoop/Fabric Assist (QLFA) QuickLoop/Fabric Assist (QLFA) connects private loop hosts to the SAN fabric for better performance and fault managem
Overview Advanced Zoning software limits access to data by segmenting a fabric into virtual private SANs. On 1 Gb/sec and 2 Gb/sec switches, softwar
SW12000 “Port” to “Area” Mapping The SW12000 16-port boards are labeled with port numbers (physical port numbers). These boards can be moved from sl
There are three types of zones enforcments: - HARD PORT – If all of the members of a zone are defined by <Domain, Port> (Referred to as zonin
Lab Excercise Using as few as four devices, set up the following configuration. - Validate that the devices are functioning correctly from the
10 1 10 -- N2 No_Module 11 1 11 -- N2 No_Module 12 1 12 -- N2 No_Module 13 1 13 id N2 Online F-
UlyssesSW0:admin> zoneadd "wwn_zone", "20:00:00:e0:8b:01:98:62; 20:00:00:20:37:d8:d6:e5; 20:00:00:20:37:d8:d6:8f" UlyssesSW0:a
PORT: 11 Not Zoned PORT: 12 Not Zoned PORT: 13 Enforcement: HARD PORT defaultSoft: 0 defaultHard: 0 POR
PORT: 3 Not Zoned PORT: 4 Not Zoned PORT: 5 Not Zoned PORT: 6 Not Zoned PORT: 7 Not Zoned PO